Blood Glucose Monitor | GM 700

1,999.00৳ 

Blood Glucose Monitor, GM 700

The GM700S is a premium meter featuring FAD-GDH reagent technology to minimize oxygen interference and keep you updated with results you can trust. Accepts a wide HCT range and comes with helpful meal markers to keep you as informed as possible.

  • Auto-Coding : Eliminates the need for manual coding and delivers maximum accuracy.
  • Wide HCT Range : Suitable for neonatal and anemic patients.
  • Various Blood Samples Accepted : Allows capillary, venous and arterial blood.
  • Complete Blood Sugar Management : Add notes, photos and status indicators for more complete entries.
  • Personalization : Set blood glucose targets and customize your measurement schedule.
  • Intuitive Statistics Dashboard : GM 700-Blood Glucose Monitor Useful data presented clearly.

Availability: 50 in stock

SKU: GM 700 Category: Tags: ,
Guaranteed Safe Checkout

Blood Glucose Monitor, GM 700

  • Test strip : GS700
  • Coding : Auto-coding
  • Enzyme / Measurement technology : GDH / Electrochemical sensor
  • Blood sample source : Capillary, venous, arterial and neonatal whole blood
  • Minimum sample volume : 0.75 µL
  • HCT range : Glucose concentrations ≦ 11.1 mmol/L (200 mg/dL), HCT range 20 – 70%
  • Glucose concentrations > 11.1 mmol/L (200 mg/dL), HCT range 20 – 60%
  • Measuring range : 0.6 – 33.3 mmol/L (10 – 600mg/dL)
  • Meter dimensions (L x W x H) : 82.0 x 45.0 x 15.5 mm (3.22 x 1.77 x 0.61 inch)
  • Display area (L x W) : 34.0 x 27.5 mm (1.34 x 1.09 inch)
  • Weight (with battery) : 48g
  • Power supply : 1 × CR2032 battery
  • Memory capacity : 500 test results with date and time
  • Operating temperature : 6 – 44℃ (43 – 111°F)
  • Operating relative humidity : 10 – 90%
  • Meter storage conditions : -10 – 60°C (14 – 140°F)
  • Test strip storage conditions : At 4 – 30°C (39 – 86°F), and below 90% relative humidity
  • Bluetooth version (For GM700SB) : 4.0
  • Accuracy : For glucose concentrations < 5.5 mmol/L (100 mg/dL), 95% of measured glucose values within ± 0.83 mmol/L (15 mg/dL) of reference measurements. For glucose concentrations ≥ 5.5 mmol/L (100 mg/dL), 95% of measured glucose values within ± 15% of reference measurements.
  • Precision : For glucose concentrations < 5.5 mmol/L (100 mg/dL), SD < 0.28 mmol/L (5 mg/dL) For glucose concentrations ≥ 5.5 mmol/L (100 mg/dL), CV < 5%
Weight 0.48 kg